BSWA308 Sound Level Meters
BSWA 308/BSWA 309 are octave sound level meters updating the dual-core (DSP+ARM) architecture to single chip ARM with float point unit, and updating all fix-point calculation to float-point, which signif cantly improves the accuracy and stability. Re-design analog front end circuit also lower the noise floor and linear range of product.
BSWA 308 is Class 1 and BSWA 309 is Class 2. Both instruments have certificated by the China CPA (Certification of Pattern Approval) and CMC (China Metrology Certification).
| Single chip high speed ARM with FPU | USB port function implemented |
| White backlight LCD | Update firmware via USB (also power supply) |
| Integral period from 1s~24h | Timer feature support auto measurement |
| 0.1s, 0.2s, 0.5s logger step added | Internal GPS (option) with GPS timing |
| 5 templates to save user setting | Single range to cover 123dB dynamic range |
| B-weighting added to meet ANSI standard | Reduce the noise floor (only for Class 1) |
| Automatic power on with external supply, ease of integration | Upper limit of measurement: 136dBrms/139dBpeak (40mV/Pa) |
Product Features:
● Class 1 (BSWA 308) and Class 2 (BSWA 309) sound level meter
● Comply with IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997
● 1/1 Octave in accordance with IEC61260-1:2014 and ANSI S1.11-2004
● Linearity range: 20dBA~134dBA (Class 1), 25dBA~136dBA (Class 2)
● Single range to cover 123dB/122dB dynamic range
● Frequency weighting A/B/C/Z. Time weighting Fast/Slow/Impulse
● 3 profile calculation in parallel with different frequency/time weighting. 14 custom define measurement
● Calculate SPL, LEQ, Max, Min, Peak, SD, SEL, E
● LN statistics and time history curve display
● User def ne integral period measurement, integral period up to 24h
● High speed ARM core with FPU (Float Point Unit) to achieve wide frequency response, large dynamic range and low noise floor
● 4G MicroSD card (TF card) mass storage
● RS-232 remote control port
● Mini thermal printer for measurement data print
● Internal GPS module (option), support GPS timing
Applications:
● Standardized noise measurement
● Environmental noise assessment
● Product noise testing
● Engineering noise reduction
Technical Parameters:
|
Specifications |
|
|
Type |
BSWA 308 |
|
Accuracy |
Class 1 (Group X) |
|
Standard |
GB/T 3785.1-2010, IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983, ANSI S1.43-1997 |
|
Octave1 |
Real-time 1/1 Octave (Option): 8 Hz~16 kHz Real-time 1/3 Octave (Option): 6.3 Hz~20 kHz GB/T 3241-2010, IEC 61260-1:2014 ANSI S1.11-2004. Base 10 system. |
|
Supplied Microphone |
MPA231T: 1/2” prepolarized measurement microphone, Class 1. Sensitivity: 40 mV/Pa. Frequency Range: 3 Hz~20 kHz. |
|
Mic Interface |
TNC connecter with ICCP power supply (4 mA) |
|
Detector / Filter |
Fully float-point digital signal processing (digital detector and filter) |
|
Integral Period |
Infinite or 1s~24h user define integral period. Repeat time: Infinite or 1~9999 |
|
Logger Step |
0.1s, 0.2s, 0.5s, 1 s~24h (Optional function) |
|
Measurement Functions |
LXY(SPL), LXeq, LXeq1s, LXIeq, LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LDay, LEvening, LNight, Ldn, Lden, LXYN. Where X is the frequency weighting: A, B, C, Z; Y is time weighting: F, S, I; N is the statistical percentage: 1~99.3 profile and 14 custom define measurement are calculate in parallel with different frequency/time weighting. (All above are optional functions, except for LXY(SPL), LXeq, LXYmax, LXYmin, LXPeak) |
|
24h Measurement |
Automatic measurement based on user define date/time and save the history data |
|
Frequency Weighting |
Parallel A, B, C, Z (It can also be applied to 1/1 and 1/3 Octave) |
|
Time Weighting |
Parallel F, S, I and Peak detection |
|
Self-Noise2 |
Sound: 19 dB(A), 25 dB(C), 31 dB(Z) Electrical: 13 dB(A), 17 dB(C), 24 dB(Z) |
|
Upper Limit2 |
136 dB(A) Increase to 154 dB(A) with 5 mV/Pa Microphone |
|
Frequency Response1 |
10 Hz ~ 20 kHz |
|
Level Linearity Range2,3,4 |
22 dB(A)~136 dB(A) Octave:30 dB~136 dB |
|
Dynamic Range2 |
123 dB (13 dB(A)~136 dB(A)) |
|
Peak C Range2,3 |
47 dB ~ 139 dB |
|
Electrical Input |
Maximum input voltage: 5 Vrms (7.07 Vpeak). Input impedance of preamplifier: >6 GΩ |
|
Range Setting |
Single range to cover whole dynamic range |
|
Resolution |
24 Bits |
|
Sampling Rate |
48 kHz (Sampling interval for LN: 20 ms) |
|
Time History |
Time domain noise curve display. Duration time: 1 min, 2 min, 10 min |
|
LCD Display |
160x160 LCD with white backlight, 14 step contrast level, 1s display update rate |
|
Mass Storage |
8 G MicroSD card (TF card) |
|
Post-processing |
Post-processing software VA-SLM can read, analyze and generate reports of store data. |
|
Export Data |
Directly connect to the computer to read the memory card (USB disk) |
|
Output |
AC Output (max 5 VRMS, ±15 mA), DC Output (10 mV/dB, max 15 mA), RS-232 serial interface and USB (USB disk mode or modem mode) |
|
Alarm |
User define alarm threshold. LED indicate the alarm status |
|
Setup Template |
5 templates to save user setup for different application, template can be save in MicroSD card |
|
Auto Power On |
Automatic power on and start measurement when power supply available, ease of integration (Optional function) |
|
Power Supply |
4x1.5 V alkaline batteries (LR6/AA/AM3), sustainable use of approx.10 hours (depends on battery). It also can be supply by external DC power (7V~14V 500 mA) and USB power (5V 1A) |
|
RTC |
Built-in backup battery has been calibrated at factory to the error <26s in 30 days (<10 ppm, (25±16) ºC). It can keep RTC running when replacing the main batteries. GPS timing function available (option with GPS module) |
|
Language |
English, Chinese, Portuguese, Spanish, German, French |
|
Firmware Update |
Update firmware via USB port |
|
Conditions |
Temperature: -10 ºC~50 ºC. Humidity: 20%~90% RH |
|
RT Temperature |
Real-time temperature display on the main screen |
|
Size (mm) |
W70 x H300 x D36 |
|
Weight |
Approx. 620 g, including 4 alkaline batteries |
|
Option |
|
|
GPS(option) |
Receiver Type: 50 Channels; Time-To-First-Fix: Cold Start 27s , Warm Start 27 s, Hot Start 1 s; Sensitivity: Tracking -161 dBm, Reacquisition -160 dBm, Cold Start -147 dBm, Hot Start -156 dBm; Horizontal position accuracy: 2.5 m, Timing accuracy: 30 ns, Velocity accuracy: 0.1 m/s; Update Rate: 1 Hz, Operation Limits: Dynamic≤4 g, Altitude<50000 m, Velocity<500 m/s |
|
Calibrator |
CA111, Class 1, 94 dB/ 114 dB, 1 kHz |
|
Printer |
Mini thermal or dot-matrix printer, RS-232 port |
|
Extension |
Extension cable (user defined length) and BM200A/B microphone boom (2m) |
Note 1: Ignore the result outside 20Hz~12.5kHz for type BSWA 309 alone due to microphone frequency response of Class 2.
|
Optional Function |
|
|
Basic (must option) |
LXY(SPL), LXeq, LXYmax, LXYmin, LXPeak. |
|
Statistical |
LXeq1s, LXIeq, LXYSD, LXSEL, LXE, LDay, LEvening, LNight, Ldn, Lden, LXYN. Where X is the frequency |
|
1/1 Octave |
Real-time 1/1 Octave, Class 1: 8 Hz~16 kHz, Class 2: 16 Hz~8 kHz |
|
1/3 Octave |
Real-time 1/3 Octave, Class 1: 6.3 Hz~20 kHz, Class 2: 16Hz~12.5 kHz |
|
Storage |
Save SWN, CSD, OCT files into MicroSD card (TF card) |
|
Auto Power On |
Automatic power on and start measurement when power supply available, ease of integration |
Download information:


BSWA308/BSWA309