BSWA308 Sound Level Meters

BSWA 308/BSWA 309 are octave sound level meters updating the dual-core (DSP+ARM) architecture to single chip ARM with float point unit, and updating all fix-point calculation to float-point, which signif cantly improves the accuracy and stability. Re-design analog front end circuit also lower the noise floor and linear range of product.

BSWA 308 is Class 1 and BSWA 309 is Class 2. Both instruments have certificated by the China CPA (Certification of Pattern Approval) and CMC (China Metrology Certification).


Single chip high speed ARM with FPU USB port function implemented
White backlight LCD Update firmware via USB (also power supply)
Integral period from 1s~24h Timer feature support auto measurement
0.1s, 0.2s, 0.5s logger step added Internal GPS (option) with GPS timing
5 templates to save user setting Single range to cover 123dB dynamic range
B-weighting added to meet ANSI standard Reduce the noise floor (only for Class 1)
Automatic power on with external supply, ease of integration Upper limit of measurement: 136dBrms/139dBpeak (40mV/Pa)


Product Features:

● Class 1 (BSWA 308) and Class 2 (BSWA 309) sound level meter

● Comply with IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997

● 1/1 Octave in accordance with IEC61260-1:2014 and ANSI S1.11-2004

● Linearity range: 20dBA~134dBA (Class 1), 25dBA~136dBA (Class 2)

● Single range to cover 123dB/122dB dynamic range

● Frequency weighting A/B/C/Z. Time weighting Fast/Slow/Impulse

● 3 profile calculation in parallel with different frequency/time weighting. 14 custom define measurement

● Calculate SPL, LEQ, Max, Min, Peak, SD, SEL, E

● LN statistics and time history curve display

● User def ne integral period measurement, integral period up to 24h

● High speed ARM core with FPU (Float Point Unit) to achieve wide frequency response, large dynamic range and low noise floor

● 4G MicroSD card (TF card) mass storage

● RS-232 remote control port

● Mini thermal printer for measurement data print

● Internal GPS module (option), support GPS timing


Applications:  

 ● Standardized noise measurement  

 ● Environmental noise assessment  

 ● Product noise testing  

 ● Engineering noise reduction


Technical Parameters:

Specifications 

Type

BSWA 308

Accuracy

Class 1  (Group X) 

Standard

GB/T 3785.1-2010, IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983, ANSI S1.43-1997

Octave1

Real-time 1/1 Octave (Option): 8 Hz~16 kHz 

 Real-time 1/3 Octave (Option): 6.3 Hz~20 kHz 

 GB/T 3241-2010, IEC 61260-1:2014 

 ANSI S1.11-2004. Base 10 system.

Supplied Microphone

MPA231T: 1/2” prepolarized measurement microphone, Class 1. Sensitivity: 40 mV/Pa. 

Frequency Range: 3 Hz~20 kHz.

Mic Interface

TNC connecter with ICCP power supply (4 mA) 

Detector / Filter

Fully float-point digital signal processing (digital detector and filter

Integral Period

Infinite or 1s~24h user define integral period. Repeat time: Infinite or 1~9999

Logger Step

0.1s, 0.2s, 0.5s, 1 s~24h (Optional function) 

Measurement Functions

LXY(SPL), LXeq, LXeq1s, LXIeq, LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LDay, LEvening, LNight, Ldn, Lden,  LXYN. Where X is the frequency weighting: A, B, C, Z; Y is time weighting: F, S, I; N is the statistical percentage: 1~99.3 profile and 14 custom define measurement are calculate in parallel with different frequency/time weighting.

 (All above are optional functions, except for LXY(SPL), LXeq, LXYmax, LXYmin, LXPeak

24h Measurement

Automatic measurement based on user define date/time and save the history data 

Frequency Weighting

Parallel A, B, C, Z (It can also be applied to 1/1 and 1/3 Octave) 

Time Weighting

Parallel F, S, I and Peak detection

Self-Noise2

Sound: 19 dB(A), 25 dB(C), 31 dB(Z)

Electrical: 13 dB(A), 17 dB(C), 24 dB(Z)

Upper Limit2

136 dB(A)

Increase to 154 dB(A) with 5 mV/Pa Microphone

Frequency Response1

10 Hz ~ 20 kHz

Level Linearity Range2,3,4

22 dB(A)~136 dB(A) Octave:30 dB~136 dB

Dynamic Range2

123 dB (13 dB(A)~136 dB(A))

Peak C Range2,3

47 dB ~ 139 dB

Electrical Input 

Maximum input voltage: 5 Vrms (7.07 Vpeak). Input impedance of preamplifier: >6 GΩ

Range Setting

Single range to cover whole dynamic range

Resolution

24 Bits

Sampling Rate

48 kHz (Sampling interval for LN: 20 ms)

Time History

Time domain noise curve display. Duration time: 1 min, 2 min, 10 min

LCD Display

160x160 LCD with white backlight, 14 step contrast level, 1s display update rate 

Mass Storage

8 G MicroSD card (TF card)

Post-processing

Post-processing software VA-SLM can read, analyze and generate reports of store data. 

Export Data

Directly connect to the computer to read the memory card (USB disk)

Output

AC Output (max 5 VRMS, ±15 mA), DC Output (10 mV/dB, max 15 mA), 

 RS-232 serial interface and USB (USB disk mode or modem mode) 

Alarm

User define alarm threshold. LED indicate the alarm status

Setup Template 

5 templates to save user setup for different application, template can be save in MicroSD card

Auto Power On

Automatic power on and start measurement when power supply available, ease of integration (Optional function) 

Power Supply

4x1.5 V alkaline batteries (LR6/AA/AM3), sustainable use of approx.10 hours (depends on battery). It also can be supply by external DC power (7V~14V 500 mA) and USB power (5V 1A)

RTC 

Built-in backup battery has been calibrated at factory to the error <26s in 30 days (<10 ppm, (25±16) ºC). It can keep RTC running when replacing the main batteries. GPS timing function available (option with GPS module) 

Language

English, Chinese, Portuguese, Spanish, German, French 

Firmware Update

Update firmware via USB port

Conditions

Temperature: -10 ºC~50 ºC. Humidity: 20%~90% RH  

RT Temperature

Real-time temperature display on the main screen  

Size (mm)

W70 x H300 x D36

Weight

Approx. 620 g, including 4 alkaline batteries

Option

GPS(option)

Receiver Type: 50 Channels; Time-To-First-Fix: Cold Start 27s , Warm Start 27 s, Hot Start 1 s; Sensitivity: Tracking -161 dBm, Reacquisition -160 dBm, Cold Start -147 dBm, Hot Start -156 dBm; Horizontal position accuracy: 2.5 m, Timing accuracy: 30 ns, Velocity accuracy: 0.1 m/s; Update Rate: 1 Hz, Operation Limits: Dynamic≤4 g, Altitude<50000 m, Velocity<500 m/s

Calibrator

CA111, Class 1, 94 dB/ 114 dB, 1 kHz

Printer 

Mini thermal or dot-matrix printer, RS-232 port

Extension

Extension cable (user defined length) and BM200A/B microphone boom (2m) 

Note 1:  Ignore the result outside 20Hz~12.5kHz for type BSWA 309 alone due to microphone frequency response of Class 2.  

Note 2: The data was measured with 40mV/Pa microphone for BSWA 308 and BSWA 309. 
Note 3: Measurement according to GB/T 3785 and IEC 61672. 
Note 4:  Measurement according to GB/T 3241 and IEC 61260.

Optional Function 

Basic (must option)

LXY(SPL), LXeq, LXYmax, LXYmin, LXPeak
Where X is the frequency weighting: A, B, C, Z; Y is time weighting: F, S, I. 

Statistical 

LXeq1s, LXIeq, LXYSD, LXSEL, LXE, LDay, LEvening, LNight, Ldn, Lden, LXYN. Where X is the frequency 
weighting: A, B, C, Z; Y is time weighting: F, S, I; N is the statistical percentage: 1~99. 3 profile and 14 custom define measurement are calculate in parallel with different frequency/time weighting. 

1/1 Octave

Real-time 1/1 Octave, Class 1: 8 Hz~16 kHz, Class 2: 16 Hz~8 kHz

1/3 Octave

Real-time 1/3 Octave, Class 1: 6.3 Hz~20 kHz, Class 2: 16Hz~12.5 kHz

Storage

Save SWN, CSD, OCT files into MicroSD card (TF card)

Auto Power On

Automatic power on and start measurement when power supply available, ease of integration


Download information: