OM226 Permanent Outdoor Microphone Class 2
OM226 permanent outdoor microphone is
developed by BSWA Tech for outdoor noise monitor. Compared with semi-permanent
outdoor microphone, the main improvement of permanent outdoor microphone is the
built-in electrostatic actuator which can be used for remote system check. The
external excitation signal source that can generate sine wave signal with
frequency of 500 Hz and amplitude of 210 Vpeak ~ 280 Vpeak (about 150 Vrms ~
200 Vrms) can excite the microphone to generate an output signal of 90 dB@1
KHz. Electrostatic actuator can be used for whole system check including
microphone, cable and measuring instrument, but it cannot completely replace
the sound calibration. Therefore, it is still necessary to use sound calibrator
for calibration regularly.
OM226 outdoor microphones have been
specially designed to achieve the free-field frequency response both in 0° and
90° direction of incidence within the limits of IEC 61672-1 Class 2. It’s
suitable for aircraft, airport, urban, traffic and industrial noise
measurement. Each microphone is supplied with an individual calibration
certificate that contains the actual sensitivity and free-field frequency
response data for the complete set of outdoor microphones. Users can use the calibration
data to correct the measurement data for more accurate results.
Features:
Meet
the requirement of IEC 61672-1 Class 2 both in 0° and 90° direction of
incidence without correction
Delivered
with individual calibration data
IP54
enclosure to against rain, dust and perching birds
The
protection kit can be quickly remove for calibration
Built-in
electrostatic actuator for remote system check (external excitation signal
source is required)
ICCP
power supply, low self-generated noise, typical noise level is ~23 dBA
It
can be installed on the tripod by 1/4-inch thread on the bottom
Applications:
Aircraft
and airport noise measurement
Urban,
traffic and industrial noise measurement
Acoustic
measurement in severe weathers
Type |
OM226 |
Application |
Aircraft, airport, urban, traffic and industrial noise measurement |
Incidence |
0° and 90° |
Standard |
GB/T 3785.1-2010 Class 2, IEC 61672-1:2013 Class 2, ANSI S1.4-1983 Type 2 |
Built-in Microphone |
1/2” Prepolarized Microphone |
Sound Field |
Free-field |
Sensitivity@250 Hz (mV/Pa) (±3 dB) |
40 (-28 dB re 1V/Pa) |
Polarization Voltage |
0 V (Prepolarized) |
Frequency Response (Hz) |
20 ~ 12.5 k (According to IEC 61672-1) |
Dynamic Range (dBA ~ dB) |
23 ~ 136 |
Self-generated Noise (dBA) |
23 |
Maximum SPL (dB) |
≥ 136 (3 % distortion) |
Peak SPL (dBA) |
139 |
Wind Noise Attenuation (dBA) |
20 (wind speed 10 m/s) |
Output Impedance |
< 30 Ω |
Maximum Output Voltage (Vpeak) |
±7.1 |
Power Supply |
ICCP (2 mA ~ 20 mA, 4 mA Typ.) |
Output Connector |
BNC (Microphone), 10-32 UNF (Actuator) |
TEDS |
Optional, IEEE 1451.4 compliant (default v0.9, optional v1.0) |
Mounting Thread for Tripod |
1/4” thread |
Enclosure |
IP54 (Microphone vertical placement only) |
Operating Temperature Range (°C) |
-30 ~ 80 |
Operating Humidity Range (%RH) |
0 ~ 95 |
Dimensions (mm) |
Ø90 x 222 (without extension rod), Ø90 x 376 (with extension rod) |
Weight (g) |
94 (without extension rod), 214 (with extension rod) |
Download information: